Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
IEEE J Biomed Health Inform ; 27(7): 3302-3313, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37067963

RESUMO

In recent years, several deep learning models have been proposed to accurately quantify and diagnose cardiac pathologies. These automated tools heavily rely on the accurate segmentation of cardiac structures in MRI images. However, segmentation of the right ventricle is challenging due to its highly complex shape and ill-defined borders. Hence, there is a need for new methods to handle such structure's geometrical and textural complexities, notably in the presence of pathologies such as Dilated Right Ventricle, Tricuspid Regurgitation, Arrhythmogenesis, Tetralogy of Fallot, and Inter-atrial Communication. The last MICCAI challenge on right ventricle segmentation was held in 2012 and included only 48 cases from a single clinical center. As part of the 12th Workshop on Statistical Atlases and Computational Models of the Heart (STACOM 2021), the M&Ms-2 challenge was organized to promote the interest of the research community around right ventricle segmentation in multi-disease, multi-view, and multi-center cardiac MRI. Three hundred sixty CMR cases, including short-axis and long-axis 4-chamber views, were collected from three Spanish hospitals using nine different scanners from three different vendors, and included a diverse set of right and left ventricle pathologies. The solutions provided by the participants show that nnU-Net achieved the best results overall. However, multi-view approaches were able to capture additional information, highlighting the need to integrate multiple cardiac diseases, views, scanners, and acquisition protocols to produce reliable automatic cardiac segmentation algorithms.


Assuntos
Aprendizado Profundo , Ventrículos do Coração , Humanos , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos , Átrios do Coração
2.
Sci Rep ; 13(1): 6285, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-37072440

RESUMO

We comprehensively studied morphological and functional aortic aging in a population study using modern three-dimensional MR imaging to allow future comparison in patients with diseases of the aortic valve or aorta. We followed 80 of 126 subjects of a population study (20 to 80 years of age at baseline) using the identical methodology 6.0 ± 0.5 years later. All underwent 3 T MRI of the thoracic aorta including 3D T1 weighted MRI (spatial resolution 1 mm3) for measuring aortic diameter and plaque thickness and 4D flow MRI (spatial/temporal resolution = 2 mm3/20 ms) for calculating global and regional aortic pulse wave velocity (PWV) and helicity of aortic blood flow. Mean diameter of the ascending aorta (AAo) decreased and plaque thickness increased significantly in the aortic arch (AA) and descending aorta (DAo) in females. PWV of the thoracic aorta increased (6.4 ± 1.5 to 7.0 ± 1.7 m/s and 6.8 ± 1.5 to 7.3 ± 1.8 m/s in females and males, respectively) over time. Local normalized helicity volumes (LNHV) decreased significantly in the AAo and AA (0.33 to 0.31 and 0.34 to 0.32 in females and 0.34 to 0.32 and 0.32 to 0.28 in males). By contrast, helicity increased significantly in the DAo in both genders (0.28 to 0.29 and 0.29 to 0.30, respectively). 3D MRI was able to characterize changes in aortic diameter, plaque thickness, PWV and helicity during six years in our population. Aortic aging determined by 3D multi-parametric MRI is now available for future comparisons in patients with diseases of the aortic valve or aorta.


Assuntos
Aorta , Análise de Onda de Pulso , Humanos , Masculino , Feminino , Pré-Escolar , Criança , Seguimentos , Velocidade do Fluxo Sanguíneo , Aorta Torácica , Imageamento por Ressonância Magnética/métodos , Envelhecimento
3.
Physiol Meas ; 44(3)2023 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-36735968

RESUMO

Objective. This study assesses age-related differences of thoracic aorta blood flow profiles and provides age- and sex-specific reference values using 4D flow cardiovascular magnetic resonance (CMR) data.Approach. 126 volunteers (age 20-80 years, female 51%) underwent 4D flow CMR and 12 perpendicular analysis planes in the thoracic aorta were specified. For these planes the following parameters were evaluated: body surface area-adjusted aortic area (A'), normalized flow displacement (NFD), the degree of wall parallelism (WPD), the minimal relative cross-sectional area through which 80% of the volume flow passes (A80) and the angle between flow direction and centerline (α).Main results. Age-related differences in blood flow parameters were seen in the ascending aorta with higher values for NFD and angle and lower values for WPD and A80 in older subjects. All parameters describing blood flow patterns correlated with the cross-sectional area in the ascending aorta. No relevant sex-differences regarding blood flow profiles were found.Significance. These age- and sex-specific reference values for quantitative parameters describing blood flow within the aorta might help to study the clinical relevance of flow profiles in the future.


Assuntos
Aorta , Hemodinâmica , Masculino , Humanos , Feminino , Idoso , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Valores de Referência , Velocidade do Fluxo Sanguíneo , Fluxo Sanguíneo Regional , Aorta/diagnóstico por imagem , Imageamento por Ressonância Magnética
4.
Int J Comput Assist Radiol Surg ; 17(3): 507-519, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35066774

RESUMO

PURPOSE: Careful assessment of the aortic root is paramount to select an appropriate prosthesis for transcatheter aortic valve implantation (TAVI). Relevant information about the aortic root anatomy, such as the aortic annulus diameter, can be extracted from pre-interventional CT. In this work, we investigate a neural network-based approach for segmenting the aortic root as a basis for obtaining these parameters. METHODS: To support valve prosthesis selection, geometric measures of the aortic root are extracted from the patient's CT scan using a cascade of convolutional neural networks (CNNs). First, the image is reduced to the aortic root, valve, and left ventricular outflow tract (LVOT); within that subimage, the aortic valve and ascending aorta are segmented; and finally, the region around the aortic annulus. From the segmented annulus region, we infer the annulus orientation using principal component analysis (PCA). The area-derived diameter of the annulus is approximated based on the segmentation of the aortic root and LVOT and the plane orientation resulting from the PCA. RESULTS: The cascade of CNNs was trained using 90 expert-annotated contrast-enhanced CT scans routinely acquired for TAVI planning. Segmentation of the aorta and valve within the region of interest achieved an F1 score of 0.94 on the test set of 36 patients. The area-derived diameter within the annulus region was determined with a mean error below 2 mm between the automatic measurement and the diameter derived from annotations. The calculated diameters and resulting errors are comparable to published results of alternative approaches. CONCLUSIONS: The cascaded neural network approach enabled the assessment of the aortic root with a relatively small training set. The processing time amounts to 30 s per patient, facilitating time-efficient, reproducible measurements. An extended training data set, including different levels of calcification or special cases (e.g., pre-implanted valves), could further improve this method's applicability and robustness.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Aorta , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos
5.
Int J Comput Assist Radiol Surg ; 14(2): 357-371, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30293173

RESUMO

PURPOSE: Various options are available for the treatment of mitral valve insufficiency, including reconstructive approaches such as annulus correction through ring implants. The correct choice of general therapy and implant is relevant for an optimal outcome. Additional to guidelines, decision support systems (DSS) can provide decision aid by means of virtual intervention planning and predictive simulations. Our approach on virtual downsizing is one of the virtual intervention tools that are part of the DSS workflow. It allows for emulating a ring implantation based on patient-specific lumen geometry and vendor-specific implants. METHODS: Our approach is fully automatic and relies on a lumen mask and an annulus contour as inputs. Both are acquired from previous DSS workflow steps. A virtual surface- and contour-based model of a vendor-specific ring design (26-40 mm) is generated. For each case, the ring geometry is positioned with respect to the original, patient-specific annulus and additional anatomical landmarks. The lumen mesh is parameterized to allow for a vertex-based deformation with respect to the user-defined annulus. Derived from post-interventional observations, specific deformation schemes are applied to atrium and ventricle and the lumen mesh is altered with respect to the ring location. RESULTS: For quantitative evaluation, the surface distance between the deformed lumen mesh and segmented post-operative echo lumen close to the annulus was computed for 11 datasets. The results indicate a good agreement. An arbitrary subset of six datasets was used for a qualitative evaluation of the complete lumen. Two domain experts compared the deformed lumen mesh with post-interventional echo images. All deformations were deemed plausible. CONCLUSION: Our approach on virtual downsizing allows for an automatic creation of plausible lumen deformations. As it takes only a few seconds to generate results, it can be added to a virtual intervention toolset without unnecessarily increasing the pipeline complexity.


Assuntos
Técnicas de Apoio para a Decisão , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Cirurgia Assistida por Computador/métodos , Humanos , Realidade Virtual
6.
Int J Comput Assist Radiol Surg ; 13(11): 1741-1754, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30074135

RESUMO

PURPOSE: The importance of mitral valve therapies is rising due to an aging population. Visualization and quantification of the valve anatomy from image acquisitions is an essential component of surgical and interventional planning. The segmentation of the mitral valve from computed tomography (CT) acquisitions is challenging due to high variation in appearance and visibility across subjects. We present a novel semi-automatic approach to segment the open-state valve in 3D CT volumes that combines user-defined landmarks to an initial valve model which is automatically adapted to the image information, even if the image data provide only partial visibility of the valve. METHODS: Context information and automatic view initialization are derived from segmentation of the left heart lumina, which incorporates topological, shape and regional information. The valve model is initialized with user-defined landmarks in views generated from the context segmentation and then adapted to the image data in an active surface approach guided by landmarks derived from sheetness analysis. The resulting model is refined by user landmarks. RESULTS: For evaluation, three clinicians segmented the open valve in 10 CT volumes of patients with mitral valve insufficiency. Despite notable differences in landmark definition, the resulting valve meshes were overall similar in appearance, with a mean surface distance of [Formula: see text] mm. Each volume could be segmented in 5-22 min. CONCLUSIONS: Our approach enables an expert user to easily segment the open mitral valve in CT data, even when image noise or low contrast limits the visibility of the valve.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Pontos de Referência Anatômicos/diagnóstico por imagem , Humanos , Imageamento Tridimensional/métodos
7.
Magn Reson Med ; 74(4): 964-70, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25302683

RESUMO

PURPOSE: To develop and evaluate a practical phase unwrapping method for real-time phase-contrast flow MRI using temporal and spatial continuity. METHODS: Real-time phase-contrast MRI of through-plane flow was performed using highly undersampled radial FLASH with phase-sensitive reconstructions by regularized nonlinear inversion. Experiments involved flow in a phantom and the human aorta (10 healthy subjects) with and without phase wrapping for velocity encodings of 100 cm·s(-1) and 200 cm·s(-1) . Phase unwrapping was performed for each individual cardiac cycle and restricted to a region of interest automatically propagated to all time frames. The algorithm exploited temporal continuity in forward and backward direction for all pixels with a "continuous" representation of blood throughout the entire cardiac cycle (inner vessel lumen). Phase inconsistencies were corrected by a comparison with values from direct spatial neighbors. The latter approach was also applied to pixels exhibiting a discontinuous signal intensity time course due to movement-induced spatial displacements (peripheral vessel zone). RESULTS: Phantom and human flow MRI data were successfully unwrapped. When halving the velocity encoding, the velocity-to-noise ratio (VNR) increased by a factor of two. CONCLUSION: The proposed phase unwrapping method for real-time flow MRI allows for measurements with reduced velocity encoding and increased VNR.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Humanos , Imagens de Fantasmas
8.
Med Image Anal ; 18(7): 1217-32, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25113321

RESUMO

The VESSEL12 (VESsel SEgmentation in the Lung) challenge objectively compares the performance of different algorithms to identify vessels in thoracic computed tomography (CT) scans. Vessel segmentation is fundamental in computer aided processing of data generated by 3D imaging modalities. As manual vessel segmentation is prohibitively time consuming, any real world application requires some form of automation. Several approaches exist for automated vessel segmentation, but judging their relative merits is difficult due to a lack of standardized evaluation. We present an annotated reference dataset containing 20 CT scans and propose nine categories to perform a comprehensive evaluation of vessel segmentation algorithms from both academia and industry. Twenty algorithms participated in the VESSEL12 challenge, held at International Symposium on Biomedical Imaging (ISBI) 2012. All results have been published at the VESSEL12 website http://vessel12.grand-challenge.org. The challenge remains ongoing and open to new participants. Our three contributions are: (1) an annotated reference dataset available online for evaluation of new algorithms; (2) a quantitative scoring system for objective comparison of algorithms; and (3) performance analysis of the strengths and weaknesses of the various vessel segmentation methods in the presence of various lung diseases.


Assuntos
Algoritmos , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Humanos , Países Baixos , Reconhecimento Automatizado de Padrão , Sensibilidade e Especificidade , Espanha
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...